ACES offer an unique quality control procedure that covers all aspects of the
remanufacturing process, in that each compressor is dealt with as an individual project.
All compressors are subject to the following individual remanufacturing process.
 
You're at Stage 1 Click here for Stage 2
Click here for Stage 3 Click here for Stage 4
Click here for Stage 5 Click here for Stage 6
Click here for Stage 7 Click here for Stage 8
Click here for Stage 9 Click here for Stage 10
Click here for Stage 11  
 
A stringent volumetric test for amperage and oil pressures on our special rig
Back to previous stage Forward to next remanufacturing stage
 

Stage 9: Test centre. Every compressor is test run under full load conditions on a closed circuit system. Currents and winding resistances are recorded together with suction, discharge and oil pressure. A final pump down completes the testing procedure after which the compressor is leak tested with OFN and dehydrated.